Classic tenders ::
Get complete information related to latest ab-switch-moving-contact Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic India tenders, private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding ab-switch-moving-contact Tenders.
Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :21088217 c-icon21 Jun, 2021 Tender Value : 5.00 Lacs
l-iconAizwal - Mizoram Tender For supply order of cat a spares partoil seal f2701400 s/a of suction pipe 7 hose –res to pump f8603400 universal joint x3958200 seal kit- side cover p2401051 seal kit p2405351 pull – off spring f3630910 spring- brake pedal return f7860900 buffer f2631400 thermostat x7468900 temperature sensor x2009400 s/a of 14” rdc clutch cover b1301501 14’ clutch disc assy b1304804 clutch withdrawal plate b1301503 king pin repair kit p0965651 end assy rh p2633339 end assy lh p2633439 oil seal f2730200 rear brake chamber lh f3r00114 rear brake chamber rh f3r00214 automatic slack adjt f8377800 rear brake lining kit p1613751 ddu f8836500 air filter primary f8211200 fuel filter cum water separator f8835100 oil filter f7a01500 hose assy – feed pump to filter b4439703 hose assy filter to fip b4439704 drive assy p3713239/26241170 solenoid switch p3702320 6” hlp brk lining kit front p4318851 frt brake camber lh f8892300 frt brake chamber rh f8892400 automatic slack adjt x8802600 front shackle bush f0530530 front shackle pin ff600110 front spring lh f9f01915 front spring rh f9f02015 rear shackle pin fb300513 cotter pin f5g00114 center bolt & nut p3202751 2nd leaf p3252445 rear spring fd300210 spring shackle f3210122 filter element p2400540 primary air filter f7b01100 safety air filter f7b01200 armature assy p3713139 armature assembling kit p3707251 brush assembling kit p3707351 bearing bush assembling kit p3707451 fasteners assembling kit p3707551 sealing assembling kit p3707651 rotor assy p3703652 rectifier assy p3703852 brush p3713545 regulator & brush box assy p3710139 de brg assembling kit p3701351 radiator hose f8p08758 radiator outlet hose f8p00154 jupiter t bolt clamp alt f4r03210 x390310 turbo out let hose f8p03700 ips oil seal f2717600 gear joint assy b1733501 automatic load sensing valve with voss ptfc f3v00100 bolt i head ¾ bsf x 11.102 long x x3502911 nut nyloc hex ¾ bsf x 0.94 long x0 f3547415 fuel stainer f8824500 s/a of hose b4464701 hose assy feed pump to fuel filter cum w/s b4464901 hose assy filter to fip b4464902 rubber ended nylon hose return liner 3750 b4453002 lamp wedge base 24v 2 watt f2316700 ignition switch & starter switch f2202200 4 st solenoid switch 24 v f7812300 micro rely 24 v alt-fj108500 f8825200 bulb for head lamp f8038000 arens control b3717103 relay head lamp 24 v x8003800 hyd jack seal kit datel ram r/ kit ser/kit/4560 starter winding assy p3703752 power steering pump assy f8394600 shackle pin fb300514 kit lining set std front lining matching 08 rivet 80 p3616351 metacone mounting f2604200 pad engine mounting f2630200 rectifier p1301852 main leaf rear p3252345

State Government

CTN :21088666 c-icon30 Jun, 2021 Tender Value : NA
l-iconSrinagar - Jammu And Kashmir Tender For supply and installation of physiotherapy equipments combination therapy equipment with electrotherapy and ultrasound 1 should have more than 25 currents forms, namely, :- monophase, diphase, sync monophase, sync diphase, short period, long period, rectangular, exponential, triangular, traebert, rectangular faradic, modulated faradic, neodynamic, tens, tens s/a/r, tens random s/a/r, tens burst s/a/r, biphasic sa, galvanic, iontophoresis, kotz russian current, bipolar interferential, classic interferential, isoplanar interferential, vectorial interferential . 2 should have diagnostic programs:- rheobase and chronaxy, rheobase and aq, diagnostics s/d curves plotting, pain points, constant voltage / constant current. 3 should have 2 independent output channels. 4 should have simultaneous therapy 5 should have touch screen with backlight. 6 should have 2 separate intensity regulators. 7 should have direct therapy keys. 8 should have protocols: objectives & indications list 9 should have memory at least 50 free locations 10 should have ultrasound treatment head approx 5 cm² 11 should have multi frequency treatment head for approx. 1& 3 mhz 12 should have duty cycle adjustable from 10 to 100% 13 modular frequency adjustable from 0 to 100 hz. ice making machine 50 kgs with ro • should have capability of producing ice cubes of 500kg/per day • should have small cube size • should have electrical consumption : 320 w • should have fully foamed, self standing housing for insulation and long term stability • should have compact design to fit into small place • should have insulated ice bins to preserve ice for longer duration • should automatically stop and start when there’s no power or water supply 2 section motorized treatment couch should be a treatment table with 2 sections; head & leg. ? should have 2 fold-down arm rests on head section. ? should have a face hole on head section with removable face holder cover. ? total length of the table should be approx 201cm head section: 46cm & leg section:101cm and breadth not to exceed 64cm. extra corporeal shockwave therapy unit • the unit should work on the electro-pneumatic based principal. • the unit should have ballistic shock wave generation system. • the unit should have pneumatic pressure adjustable from 1.5 bar to 4 bar. • the unit should have multiple pulse operating mode • should have repetition rate for frequency of 1hz -20hz • should have pre-setting of impulses with frequency. • should have compressed air supply range of 5-6 bar • should have at least 15 treatment protocols with preset recommended settings. • should have minimum 200 personalized treatment protocols • should have at least 2500 patients’ files with automatic treatment history storage. • should have usb memory port to upgrade software and easily export data. • should display the flux density mj/mm square on the display screen. • should have complete therapeutic guide of clinical data, contraindication and scientific publications for each indications. • the unit should have touch screen panel with lcd/led display. • the unit should be mounted on customised wheel cart for easy transportation of the equipment along with the compartment for compressor. • should have the provision to set the number of pulses from 500 to 2500 & should have an increase of 500 pulses per step. • the shockwave applicators should have the impulse counters on the hand unit • the shockwave applicator hand unit should have a soft covering to absorb the shock impact • the unit should be supplied with the customized transportation case for the main equipment. • should be able to show the remaining pulses by blinking leds high power laser unit • required a class iv therapeutic laser of high efficacy. • should have wavelengths of 980 nm+ 810 nm. 980 nm for increasing the pain threshold and 810 nm for the therapeutic effect. • should have at least 12000 mw of output power to treat ailments seated deep inside the body. • should have continuous and pulsed mode. • should have emission frequency adjustable from 100 to 10000 hz . • should have duty cycle adjustable from 10 to 100%. • should have a fiber optic integrated output manipole. • should have standard protocols based on morphology. • should also have user programmable memory and favorites for consistency and eased of operation. • should have large colour lcd touch screen display for ease of operation with help on screen. • should be supplied with adjustable spacers to vary spot size at least in three sizes. • equipment must have emergency stop switch and foot pedal operation. • must be supplied with laser safety goggles for therapist and patient. should haveeuropean ce/us fda and iso certification. portable ultrasound • frequency: 1 & 3 mhz • emission: continuous and pulsed ultrasound 20% to 80% • multi frequency head area 5 cm2 1-3 mhz working in single or differently combined. • modulation from 1 to 200 hz • automatic calculation of depth and energy density • automatic power switch off • timer upto 30 min • display: graphic & coloured lcd • unlimited memories to store the patient data file • pre-set protocols with maps for placements of electrodes • intensity: 3 w cm2 in both continuous and pulsed modes • real-time device with indication of correct contact between coupling of head and patient’s skin • should be supplied with static head/elastic strap for hands free treatment. • iec protection class: 1 bf • international safety standards: european ce rehab and wellness station/thera band station • 2-42” wall slide connect track. • 1-18” slide connect overhang track. • 1-24” adjustable slide connect cross bar track. 2 channel heat therapy unit with vibration + magnetism • combination therapy unit with heat, magnetic force and micro vibrations. • the system should be modern with touch button operation and led display. • the system should consist of four channel unit with 4 hot packs in two sizes for simultaneous use. • it should have flexible heating pads giving dry heat so that it can be used over clothes in normal conditions. • the heating pads should have four steps temperature control from 35º to 60ºc. in 4 steps .maximum temperature should not exceed 62ºc for patient protection. • it should provide vibrations through flexible heating. • the system should have three different types of micro vibrations as below : - ripple wave : - 70 vibrations per second - random wave : - 120 vibrations per second - big wave : - 60 vibrations per second • it should have inbuilt magnetic force for improving the blood flow. • micro vibration should be from alternating magnetic field only for a pleasant stimulus to a diseased part.. • it should have digital timer of 30 minutes duration. • it should be supplied with an imported trolley and should work on 110-240 v &50/60 hz power supply. • it should ul and iso 13485 approved for patient safety. • safety class strictly according to iec 6060-1, class 1, type -b • main unit should be light weighing not more than 20 kg. • performance certificate from reputed government hospitals should be enclosed in the tender. • the system should be supplied with the following 1. standard hot pack with cover 02 2. large hot pack with cover 02 3. belts large 02 4. belts small 02 5. pad for knee and shoulder 01 6. pad for cervical 01 7. imported trolley 01 8. magnet detector 01 9. power cord 01 10. user manual 01 for khelo india state centre of excellence jk sports council fencing academy m.a stadium
 Loading, Please wait...

Connect us via What's Up