Get complete information related to latest ac-control-panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic India tenders, private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding ac-control-panel Tenders.
Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :21087805 c-icon17 Jun, 2021 Tender Value : NA
l-iconKaushambi - Uttar Pradesh Tender For providing and retrofittings commissioning and testing of 03 nos o/c, e/f relays in 33kv tripple feeder panel at 132 kv s/s manjhanpur opening of termination of control cables and existing electromechanical relay & concerned master trip relays. removal of old relays & housing of old relay from panel cabinet. preparation of panel front by cutting & adding new m.s sheet for placement of housing of new numerical relays & master trip relays for proper mounting on panel front & covering with beading. preparation of interconnection drawing & modification in panel wiring of the numerical relays to be installed on two different panel in place of old electromechanical relays. the work includes submission of drawings, connection/termination as approved by department. supply, erection, testing & commissioning of new numerical over current relays of upptcl approved vendor make like m/s siemens/ge/abb/alstom/erl etc. supply, erection, testing & commissioning of new master trip relays of upptcl approved vendor make like m/s siemens/ge/abb/alstom/erl etc. providing and fixing of blinking type buzzer & its indicator, testing and troble shooting of alarm function with indication of 33 kv feeders through 33 kv vcb and c&r panel by cross checking of all electrical connections etc. & replacement of cable if required to complete the job satisfactorily.

State Government

CTN :21088666 c-icon30 Jun, 2021 Tender Value : NA
l-iconSrinagar - Jammu And Kashmir Tender For supply and installation of physiotherapy equipments combination therapy equipment with electrotherapy and ultrasound 1 should have more than 25 currents forms, namely, :- monophase, diphase, sync monophase, sync diphase, short period, long period, rectangular, exponential, triangular, traebert, rectangular faradic, modulated faradic, neodynamic, tens, tens s/a/r, tens random s/a/r, tens burst s/a/r, biphasic sa, galvanic, iontophoresis, kotz russian current, bipolar interferential, classic interferential, isoplanar interferential, vectorial interferential . 2 should have diagnostic programs:- rheobase and chronaxy, rheobase and aq, diagnostics s/d curves plotting, pain points, constant voltage / constant current. 3 should have 2 independent output channels. 4 should have simultaneous therapy 5 should have touch screen with backlight. 6 should have 2 separate intensity regulators. 7 should have direct therapy keys. 8 should have protocols: objectives & indications list 9 should have memory at least 50 free locations 10 should have ultrasound treatment head approx 5 cm² 11 should have multi frequency treatment head for approx. 1& 3 mhz 12 should have duty cycle adjustable from 10 to 100% 13 modular frequency adjustable from 0 to 100 hz. ice making machine 50 kgs with ro • should have capability of producing ice cubes of 500kg/per day • should have small cube size • should have electrical consumption : 320 w • should have fully foamed, self standing housing for insulation and long term stability • should have compact design to fit into small place • should have insulated ice bins to preserve ice for longer duration • should automatically stop and start when there’s no power or water supply 2 section motorized treatment couch should be a treatment table with 2 sections; head & leg. ? should have 2 fold-down arm rests on head section. ? should have a face hole on head section with removable face holder cover. ? total length of the table should be approx 201cm head section: 46cm & leg section:101cm and breadth not to exceed 64cm. extra corporeal shockwave therapy unit • the unit should work on the electro-pneumatic based principal. • the unit should have ballistic shock wave generation system. • the unit should have pneumatic pressure adjustable from 1.5 bar to 4 bar. • the unit should have multiple pulse operating mode • should have repetition rate for frequency of 1hz -20hz • should have pre-setting of impulses with frequency. • should have compressed air supply range of 5-6 bar • should have at least 15 treatment protocols with preset recommended settings. • should have minimum 200 personalized treatment protocols • should have at least 2500 patients’ files with automatic treatment history storage. • should have usb memory port to upgrade software and easily export data. • should display the flux density mj/mm square on the display screen. • should have complete therapeutic guide of clinical data, contraindication and scientific publications for each indications. • the unit should have touch screen panel with lcd/led display. • the unit should be mounted on customised wheel cart for easy transportation of the equipment along with the compartment for compressor. • should have the provision to set the number of pulses from 500 to 2500 & should have an increase of 500 pulses per step. • the shockwave applicators should have the impulse counters on the hand unit • the shockwave applicator hand unit should have a soft covering to absorb the shock impact • the unit should be supplied with the customized transportation case for the main equipment. • should be able to show the remaining pulses by blinking leds high power laser unit • required a class iv therapeutic laser of high efficacy. • should have wavelengths of 980 nm+ 810 nm. 980 nm for increasing the pain threshold and 810 nm for the therapeutic effect. • should have at least 12000 mw of output power to treat ailments seated deep inside the body. • should have continuous and pulsed mode. • should have emission frequency adjustable from 100 to 10000 hz . • should have duty cycle adjustable from 10 to 100%. • should have a fiber optic integrated output manipole. • should have standard protocols based on morphology. • should also have user programmable memory and favorites for consistency and eased of operation. • should have large colour lcd touch screen display for ease of operation with help on screen. • should be supplied with adjustable spacers to vary spot size at least in three sizes. • equipment must have emergency stop switch and foot pedal operation. • must be supplied with laser safety goggles for therapist and patient. should haveeuropean ce/us fda and iso certification. portable ultrasound • frequency: 1 & 3 mhz • emission: continuous and pulsed ultrasound 20% to 80% • multi frequency head area 5 cm2 1-3 mhz working in single or differently combined. • modulation from 1 to 200 hz • automatic calculation of depth and energy density • automatic power switch off • timer upto 30 min • display: graphic & coloured lcd • unlimited memories to store the patient data file • pre-set protocols with maps for placements of electrodes • intensity: 3 w cm2 in both continuous and pulsed modes • real-time device with indication of correct contact between coupling of head and patient’s skin • should be supplied with static head/elastic strap for hands free treatment. • iec protection class: 1 bf • international safety standards: european ce rehab and wellness station/thera band station • 2-42” wall slide connect track. • 1-18” slide connect overhang track. • 1-24” adjustable slide connect cross bar track. 2 channel heat therapy unit with vibration + magnetism • combination therapy unit with heat, magnetic force and micro vibrations. • the system should be modern with touch button operation and led display. • the system should consist of four channel unit with 4 hot packs in two sizes for simultaneous use. • it should have flexible heating pads giving dry heat so that it can be used over clothes in normal conditions. • the heating pads should have four steps temperature control from 35º to 60ºc. in 4 steps .maximum temperature should not exceed 62ºc for patient protection. • it should provide vibrations through flexible heating. • the system should have three different types of micro vibrations as below : - ripple wave : - 70 vibrations per second - random wave : - 120 vibrations per second - big wave : - 60 vibrations per second • it should have inbuilt magnetic force for improving the blood flow. • micro vibration should be from alternating magnetic field only for a pleasant stimulus to a diseased part.. • it should have digital timer of 30 minutes duration. • it should be supplied with an imported trolley and should work on 110-240 v &50/60 hz power supply. • it should ul and iso 13485 approved for patient safety. • safety class strictly according to iec 6060-1, class 1, type -b • main unit should be light weighing not more than 20 kg. • performance certificate from reputed government hospitals should be enclosed in the tender. • the system should be supplied with the following 1. standard hot pack with cover 02 2. large hot pack with cover 02 3. belts large 02 4. belts small 02 5. pad for knee and shoulder 01 6. pad for cervical 01 7. imported trolley 01 8. magnet detector 01 9. power cord 01 10. user manual 01 for khelo india state centre of excellence jk sports council fencing academy m.a stadium

State Government

CTN :21088432 c-icon18 Jun, 2021 Tender Value : NA
l-iconBageshwar - Uttaranchal Tender For construction installation of 06 bed icu demolishing brick work in cement mortar manually by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs compete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of engineer-in-charge. brick work with common burnt clay f.p.s. non modular bricks with cement mortar 1:4 1 cement : 4 coarse sand 12mm thick cement plaster of mix 1:6 1 cement : 6 fine sand providing and fixing of 1st class glazed ceramic wall tiles confirming to is standards, colour as per site requirement or approved by engineer-in-charge, over 12mm thick bed of cement mortar 1:3.mortar modular ceiling & wall partition panels: pre fabricated modular ceiling panels 50 mm thick puf panels between two sheets of 0.5mm ppgi/gi having puf density of 40kg/m3 with proper supports. ceiling panels will be fixed to the ceiling with channels, hangers & anchor fastner and interlocked with each other. panels including cutouts for lights, fans, ac grills etc as/if required. antibecterial paint: filling of all joints & cavities with metallic body filler on panels and wall putty on cemented walls and sanded flush to make smooth finish and coated with one coat of primer and 3 coat of antibecterial paint made of skk japan/ jotun. antistatic vinyl : seamless antistatic vinyl system on floor and wall upto 4 feet, 2mm thick homogenous vinyl, with perfectly curved flush rubber covings and, all joints welded properly including wall scatting. flooring wii be seamless with perfectly curved flash-covings, resistance to mechanical stress and dynamic loads and having becteria protection characteristics, 2mm thick, washable vinyl. it complies with en 649. vacuum system the medical vacuum system shall ensure the minimum pipeline. vacuum level of 450mmhg is maintained at the plant service connection point at the rated volumetric ‘free air’ flow rate with two pumps in standby. the bacteria filtration system shall be fitted in pipeline. two vacuum pumps shall be air-cooled, oil lubricated rotary vane type suitable for both continuous and frequent start/stop operation at nominal inlet vacuum levels of between 570mmhg and 720mmhg approx. central vacuum system with dual vacuum pump ir/aneast-iwata of vacuum of 745mm, with three phase motor 7.5 hp, storage tank of 1000 litre, and all required accessories vacuum gauge, vacuum pressure switch, silencer etc. cascading of vacuum pumps shall be achieved by measuring the vacuum level at the plant inlet with a pressure transducer. a mechanical back-up facility shall ensure continued operation in the event of a control system malfunction. the control system shall normally employ automatic rotation of the lead pump to maximise pump life and ensure even wear. vacuum filter station imported domnick hunter/ nitrogenium/trident make or equivalent . these filters are optimised for high-efficient removal of bacterial and other contamination solids and liquids from the suction side of vacuum pumps preventing damage to the pump and the potential biological infection of the surrounding environment. removed liquids are collected in a transparent flask which can be removed for sterilisation.the efficiency of the installed filter elements exceeds the 0, 005% penetration specified in htm 2022 for infectious disease units, when tested in accordance with bs 3928. gas specific terminal vacuum outlets with probes/adapters are designed & manufacturerd as per bs en13485. outlets shall be manufactured with a copper inlet pipe stub which is silver brazed to the outlet body. body shall be of one piece brass construction. for positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall have break safe mechanism and also comply to en 737 pressure test standards and rated at minimum 200 psi in the event the primary check valve is removed for maintenance. the outlet assembly should have separate colour coding for each services and will accept only corresponding gas specific adaptors. all outlets shall be cleaned and de-greased for medical gas service, factory assembled and tested. the medical gas outlets should be of quick connecting and wall mounted modular type. flexible tubing having antistatic core as per iso with proper colour coded complete as per specifications. electrical distribution panel based on plc for controlling of vacuum pumps with electrical safety devices. the electrical control panel will be used for cascading of two vacuum pumps and electrical safety from abnormal electrical supply, single phase preventing system, phase reverse protection. electrical panel must have display for voltage and indicators. gas terminal oxygen outlets with probes/adapters complete as per specifications. all terminal units should conform to bs standards. terminal units intended for installation with the socket axis horizontal, ie wall mounted, include a non-swivel device so that directly connected equipment such as flow meters remain vertical; terminal units intended for installation with the socket axis vertical, for example in certain types of pendant, do not include a non-swivel device. medical graded copper pipes maxflow/rajco/mandev or equivalent shall be solid drawn, tempered, seamless, phosphorous deoxidized, non-arsenic and degreased for oxygen service. distribution copper pipe manufactured as per bsen:13348:2001. adequate supports shall be provided while laying pipelines to ensure that the pipes do not sag. all exposed pipes should be painted with two coats of synthetic enamel paint and colour codification. 22m od x 0.9 mm thk 15mm od x 0.9 mm thk 12mm od x 0.7 mm thk gas alarm panel to indicate any abnormality of gas pressures and other failures of the system. the alarm system shall be complete with display, sensor module and power supply. the alarm shall be complete with all indications controls, wirings, accessories etc. complete as required. 2 gas alarm panel with analog gauge display & hi-low-normal status. area valve box - 2 gas services with complete fittings, shaddles, pipes, gauge analog, without valves. valve box housing must be made of galvanized steel duly powder coated. isolation valve complete. the isolation valves will be non lubricated, 90 degree turn level, ball type, suitable for oxygen service. all valves shall be pneumatically tested for twice the working pressure and factory degreased for medical gas service before supply. 22 mm valve with brass nut & nipple 15 mm valve with brass nut & nipple butterfly valve with brass nut & nipple accessories oxygen bpc flowmeter with humidifier 0-15 litres/minute with adapter, tubing etc. back pressure compensated flow meter will be of accurate gas flow measurement with following features: control within a range of 0 – 15 lpm calibration within +/- 10% . it will meet strict precision and durability standard. the flow tube and shroud components shall be made of clear, impact resistant polycarbonate. flow tube shall have large and expanded 0 – 5 lpm range for improved readability at low flows. the humidifier bottle shall be made of unbreakable polycarbonate material and autoclavable at 121 degree centigrade temperature. ward vacuum unit 600ml wall mounted type. ward vacuum unit shall be of light weight and compact. the unit will consist of a regulator, 600 ml reusable collection jar, made of unbreakable poly carbonate material and fully autoclavable at 134 degree centigrade. a wall bracket for mounting the jar assembly on the wall. the vacuum regulator shall be infinitely adjustable and have vacuum gauge which indicates suction supplied by the regulator. safety trap shall be provided inside the jar to safeguard the regulator from overflowing. horizontal bed head panels 5 feet long for installation of outlets with provision for mounting necessary gas outlets. the bed head panel will be provided with cutout provision of electrical points, switches, wiring etc . the panels will be made in extruded aluminium profiles with powder coating and will have cutout provision for gas outlets, provision & fixing of electrical sockets 6/16 amp - 8 nos, one basket, one suction bottle clamp slider, cutout provision for nurse call system. nurse calling system 6 beded: hospital nurse calling system including call unit & indicator on each bed and main display unit with bed number at nursing station including power supply & wiring etc. track curtain partition system: bed partion system with aluminium extruded track system mounted in ceiling with all required hardware and stain free washable fabric curtains with net on top side. air conditioning: ceiling mounted cassette type inverter ac air conditioning: ceiling mounted cassette type inverter ac unit 3 star 2 tr with r410a. it provides 360 degree air flow with improved temperature distribution. sealed hinged door: manual sealed hinged door with ss sheet/ hpl sheet on both side & puf/honeycomb material will be filled between two sheets, door size 1500mm wide 2100mm height complete with double toughned glass vision window of 300mm x 300mm, ss door hinges make dorset/dorma, ss handle, door closer make dorset/dorma, door lock make dorset/dorma, sealing gaskett & automatic drop seal in bottom of door with required accessories. door frame will be aluminium extruded profile duly anodized/ ss304 with sealing gasket. sealed insulated glass window with motorized blind view window: - double insulated fixed glazing with not less than 5mm thick toughened glass on both the sides. window frame is powdered coated aluminium of approved shape flush mounted with wall panelling. motorized venetion blind between two glasses operated by wall mounted switch or remote. size of window - 1200mm x 1200mm electrical wiring internal electrical wiring as per requirement of icu, wiring make- finolex, havells, hpl, elecrical switch- sockets make- crabtree/north-west, anchor, with ot distribution electrical panel, ceiling lights led in ceiling of icu- 16 nos. power cable at ot with main distribution panel will be provided by customer manual surgical scrub station- 1 bay supply of creative-standard surgical scrub sink wall mounted, 1- bay made out of 16gauge ss304 stainless steel seamless welding, polished to stain finish complete with y strainers, jaquar make spouts & manual foot operated valve vijay-make system, non- corrosive metal composite pipe system with brass fittings.l- 1000mm x h-1380mm x d-575mm other items icu electronic bed with full five function- up- down adjustment, back rest adjustment, leg rest adjustment, trendlberg, reverse trendlberg operated by electronic remote and mounted on 125mm castors, 2 will be with brake, abs side railing, abs panel on head & leg. icu bed side locker deluxe type with one drawer and one cabinet, duly powder coated, mounted on rubber stamps. icu over bed table with laminated top and height adjusted thru manual geared handle, duly powder coated, mounted on 50 mm castors. instrument cabinet for icu for storage of medical equipments made of stainless steel ss304 and toughned glass. 3 seater waiting chair heavy duty made of stainless steel perforated sheet and heavy hand rest made of stainless steel. 10 kva on-line uninterrupted power supply ups with sinewave output, display unit and sealed maintenance free batteries with auto redundancy system, complete with wiring, trolley and installation. modular wall & ceiling panels: pre fabricated modular wall panels 80 mm thick puf panels between two sheets of 0.5mm ppgi/gi having puf density of approx 40kg/m3 with proper channel supports. ceiling panels will be 83mm 60+23mm thick puf corrugated between two sheets of 0.5mm ppgi having density of approx 40kg/m3 fixed to the wall thru channels, hangers & anchor fastner and interlocked with each other. panels including electrical conduits inside. and filling of all joints with silicon sealant. ms pipe structure, ppgi channels, supports, anchor fastners, rivets, hardware etc aluminium coving for all corners, made out of aluminium extruded profiles duly powder coated. complete electrical job including electrical wiring for lights and fans, supply of 4 nos ceiling fans, ceiling led surface lights 8 nos, wall switches and sockets for each bed. manual hinged aluminium door with compact high pressure laminate on bottom side and glass on top side or as per requirement of site, door size as per site approx 1500mm x2100mm complete with ss door hinges, ss handle, door closer, door lock with required accessories. door frame will be aluminium extruded profile duly anodized/ powder coated. openable sliding aluminium window with double slide, one for mosquito jali and one for glass as per requirement of site. window will be with aluminium moulded grill. window size as per site approx 900mm x900mm. mounted flush in modular wall paneling.

State Government

CTN :21087917 c-icon17 Jun, 2021 Tender Value : NA
l-iconJammu - Jammu And Kashmir Tender For supply of electrical items and hardware items 33 kv & 11 kv cable kits indoor/outdoor make hot set or any other reputed make conforming to relevant is specifications raychem, 3m, densen or equivalent a cable kits 33 kv single core heat shrinkable indoor 630 mm2 b cable kits 33 kv single core heat shrinkable indoor 300 mm2 c cable kits 33 kv single core heat shrinkable outdoor 630 mm2 d cable kits 33 kv single core heat shrinkable outdoor 300 mm2 e cable kits 11 kv single core heat shrinkable indoor 630 mm2 f cable kits 11 kv single core heat shrinkable outdoor 630 mm2 g cable kits 11 kv 3 core heat shrinkable indoor 400 mm2 h cable kits 11 kv 3 core heat shrinkable indoor 300 mm2 i cable kits 11 kv 3 core heat shrinkable indoor 240 mm2 j cable kits 11 kv 3 core heat shrinkable indoor 185 mm2 k cable kits 11 kv 3 core heat shrinkable indoor 120 mm2 l cable kits 11 kv 3 core heat shrinkable outdoor 400 mm2 m cable kits 11 kv 3 core heat shrinkable outdoor 300 mm2 n cable kits 11 kv 3 core heat shrinkable outdoor 240 mm2 o cable kits 11 kv 3 core heat shrinkable outdoor 185 mm2 p cable kits 11 kv 3 core heat shrinkable outdoor 120 mm2 q cable kits 11 kv 3 core straight through joining, heat shrinkable 185 mm2 r cable kits 11 kv 3 core straight through joining, heat shrinkable 300 mm2 s cable kits 11 kv 3 core straight through joining, heat shrinkable 400 mm2 t cable kits 11 kv single core straight through joining, heat shrinkable 630 mm2 u cable kits 33 kv single core straight through joining, heat shrinkable 630 mm2 spares for 33 kv c&r panels and 11 kv vcb/ocb panel banks. a inner baffle for 33 kv mocb bhel c grid spout assembly suitable for 11 kv ocb panel bhel make d grid spout assembly suitable for 11 kv ocb panel bicco lawrie make e grid spout assembly suitable for 11 kv ocb panel crompton greaves make f trolly copper bushing rod suitable for11 kv ocb panel ssg make parma wood/crompton greaves make g male contact for 11 kv ocb bicco lawrie make copper with silver coating 11 ocb panel h male contact for 11 kv ocb s.s.g make top tip of iron with silver coating i male contact for 11 kv ocb crompton greaves make with silver coating j male contact for 11 kv ocb bhel make with silver coating j male contact for ocb mei make with silver coating k female contact for 11 kv ocb bicco lawrie make with silver coating l female contact for 11 kv ocb s.s.g make with silver coating m female contact for 11 kv ocb cromption greaves make with silver coating n female contact for 11 kv ocb bhel make with silver coating o trip bridge assembly bl p roller assembly bl q female contact for 11 kv ocb mei make with silver coating r 11 kv pt fuse s 11 kv vcb bottle assembly bracket t shower contact mei make u shower contact crompton greaves make v arc pot mei make w tripping coil suitable for 33 kv and 11 kv ocb / vcb panels operating voltage 30-36 volt dc x tripping coil for 66 kv ocb / vcb panels 11 kv cts of different ratios, make mei/ bicco lawrie / crompton greaves / bhel/ er/ ssg/ alstorm/ megawin/ sudhir/electricfield for 11 kv ocb/ vcb panels i 800/400/5-5 ii 750/375/5-5 iii 600/300/5-5 iv 400/200/5-5 v 300/150/5-5 vi 150/75/5-5 spares for power transformers a breather for 6.3 mva 33/11 kv transformer 2 kg b breather for 10 mva 33/11 kv transformer 3 kg c breather for 5 mva 33/11 kv transformer 2 kg c breather for 5 mva 66/11 kv transformer 3 kg c breather for 6.3 mva 66/11 kv transformer 3 kg c breather for 10 mva 66/11 kv transformer 3 kg d 20 mm lt bush rod for 33/11 kv transformer e 12 mm lt bush rod for 33/11 kv transformer f 20 mm copper bush rod assembly for 33/11 kv, 10 mva power transformer with oil seal g silica gel h oil seal for 33/11 kv power transformer i adaptor for bush rod extension for 33/11 kv power transformers oil temperature indicator 6-inch dia winding temperature indicator 6-inch dia relays a numerical relay 3-pole 24-50 v 2 o/c and 1 e/f relay mit 103/asida b master trip relay 24-50 v, b-24 c master trip relay ashida make 18-52 v d ashida numerical relay 2 o/c & 1 e/f 33 kv & 11 kv insulators make iec, bhel, rastriya, top line, tcpl or any other reputed make conforming to relevant is specification a 33 kv pin insulator with pins porcelain type b 33kv pin insulators for panther conductor with pins polymer type with base pin 25 mm c 33kv pin insulators for wolf conductor with pins polymer type with base pin 25 mm d 33kv pin insulators for dog conductor with pins polymer type e 33 kv g.i. pins f 11 kv pin insulator polymer type with pins g 11 kv pin insulator porcelain type with pins h 11 kv g.i. pins i 11 kv disc insulator b & s type 70 kn porcelain type j 33kv disc insulators polymer type k 33 kv post insulator l 22 kv post insulator m 11 kv post insulator n drive insulator of sorts o 11 kv guy insulator p 33 kv guy insulator 33 kv tension fittings for acsr dog conductor, b&s 3 u-bolts type approx. 2.8 kg 33 kv tension fittings for acsr wolf conductor, b&s 4 u-bolts type approx. 3.8 kg 33 kv tension fittings for acsr panther conductor, b&s 4 u-bolts type approx. 4.6 kg 33 kv suspension fittings for acsr dog conductor 33 kv suspension fittings for acsr wolf conductor 33 kv suspension fittings for acsr panther conductor hardware & clamps for conductor a 33 kv isolator clamps for acsr dog conductor heavy duty b 33 kv isolator clamps for acsr wolf conductor heavy duty c 33 kv isolator clamps for acsr panther conductor heavy duty d 33 kv pt clamps for acsr panther conductor heavy duty e 33 kv pt clamps for acsr wolf conductor heavy duty f 33 kv pt clamps for acsr dog conductor heavy duty g 33 kv ct clamps for acsr panther conductor heavy duty h 33 kv ct clamps for acsr wolf conductorheavy duty i 33 kv ct clamps for acsr dog conductorheavy duty j 33 kv la clamp for acsr panther conductor heavy duty k 33 kv la clamp for acsr wolf conductor heavy duty l 33 kv la clamp for acsr dog conductor heavy duty m t-clamps for acsr panther conductor heavy duty n t-clamps for acsr wolf conductor heavy duty o t-clamps for acsr dog conductor heavy duty p pg clamps for panther conductor heavy duty q pg clamps for wolf conductor heavy duty r pg clamps for dog conductor heavy duty nuts & bolts 4/8, 5/8 & 6/8 dia of different lengths full threaded galvanized nuts & bolts of different lengths full threaded g.i. spring washers aluminium thimble 95mm2 aluminium thimble 120mm2 aluminium thimble 185mm2 aluminium thimble 240mm2 aluminium thimble 300mm2 aluminium thimble 400mm2 aluminium thimble 630mm2 paints make asian, burger, nerolac or any other reputed make conforming to relevant is specifications a aluminium paint b red oxide paint c black paint cold galvanizing compound cold galvanizing compound for anti corrosive galvanized protection to steel structure, dried flow of compound containing 95% metallic zinc m-seal welding rod 3.5 / 4 mm electrode pvc tape empire tape para plast compound earth wire guy wire 7/16 g.i. wire 8swg of sorts barbed wire manilla rope 1 inch thick manilla rope 1½ inch thick p.p. rope 1 inch thick p.p. rope 1½ inch thick emergency lights insulation rubber mat 1 m x 2m x 12mm thick rubber boots search light / dragon light with in built charging system hand gloves 33 kv safety belts of standard quality safety helmets of standard quality megger 5000 v tool kit complete with tool box drill bit 18/20/25/28mm i/c switch 200 amp fire extinguisher for electrical sub stations of relevant is specifications aco2 4.5 kg b power based abc type 4 kg. c power based abc type 6 kg. d power based abc type 9 kg. fire buckets with stand anti climbing device turn table aluminium jointing sleeve mid span compressor joint for panther conductor 11 kv isolators & 33 kv isolators a 11 kv isolator with earthing blade 630 amp polymer b 11 kv isolator without earthing blade 630 amp polymer c 33 kv isolator with earthing blade 1250 amp polymer d 33 kv isolator without earthing blade 1250 amp polymer e 11 kv isolator 600 amps with 25 ka breaking capacity double break type with complete manual operating mechanism. 11 kv hg set 11 kv do set 11 kv g.o set 11 kv link set with 50 mm copper strip 33 kv isolator jaws plate type heavy duty 33 kv isolator jaws pipe type heavy duty battery chargers & batery bank & ac / dc distribution board a 36 volts battery bank 100 ah, 2 v, 18 nos cells complete with all accessories b 30 amp manually operated battery charger. c maintenance free 30 v lead acid battery vrla bank comprising of 16 nos of 2 volt cells of 100 ah capacity d 30 v battery charger automatic float & boost compatible for vrla batteries e 30 volt, dc distribution board indoor type, floor mounted made out of 14/16 swg crc sheet, dust, vermin proof, duly powder coated and wired as per standard engineering practice f ac distribution board indoor type, floor mounted made out of 14/16 swg crc sheet, dust, vermin proof, duly powder coated and wired as per standard engineering practice lightening arrestors 10 ka, make oblum / raychem / rashtriya / adinath / or any other reputed make conforming to relevant is specifications, compatible strictly for safety of system a 11 kv l.a. set station type polymer make oblum / raychem / rashtriya / adinath / or any other reputed make conforming to relevant is specifications, compatible strictly for safety of system b 33 kv l.a. set station type polymer make oblum / raychem / rashtriya / adinath / or any other reputed make conforming to relevant is specifications, compatible strictly for safety of system c 11 kv l.a. set station type porcelain make oblum / raychem / rashtriya / adinath / or any other reputed make conforming to relevant is specifications, compatible strictly for safety of system d 33 kv l.a. set station type porcelain make oblum / raychem / rashtriya / adinath / or any other reputed make conforming to relevant is specifications, compatible strictly for safety of system control cable armoured a 2.5 mm2 cu 2-core b 2.5 mm2 cu 4-core c 2.5 mm2 cu 6-core d 2.5 mm2 cu 8-core e 2.5 mm2 cu 10-core f 2.5 mm2 cu 12-core g 2.5 mm2 cu 16-core control cable unarmoured a 2.5 mm2 cu 2-core b 2.5 mm2 cu 4-core c 2.5 mm2 cu 6-core d 2.5 mm2 cu 8-core e 2.5 mm2 cu 10-core f 2.5 mm2 cu 12-core g 2.5 mm2 cu 16-core 11 kv vacume interupter bottle 1200a a g.e.c. b crompton greaves c allind d alstrom e bhel /a.b.b 11 kv vacume interupter bottle 800a a g.e.c. b crompton greaves c allind d alstrom e bhel /a.b.b h.t. tape 33 kv xlpe power cable make havells or any other reputed make conforming to relevant is specifications a 33 kv single phase xlpe cable 630 mm2 b 11 kv single-core xlpe cable 630 mm2 c 11 kv 3-core xlpe cable 400 mm2 d 11 kv 3-core xlpe cable 300 mm2 e 11 kv 3-core xlpe cable 240 mm2 f 11 kv 3-core xlpe cable 185 mm2 g 11 kv 3-core xlpe cable 120 mm2 h 11 kv 3-core xlpe cable 95 mm2 twin core 16 mm2 pvc cable al pvc cable 3.5 core armoured x35 sqmm pvc cable 4 core armoured 16mm² 3.5 core lt cable 50 mm² armoured earthing material a charcoal b salt c g.i. plate 2x 2 d g.i. pipe 40 mm f 1½ e g.i. pipe 50 mm f 2 f g.i. strip 25x3 mm g g.i. strip 50x6 mm / 25x6 mm g.i. flat 50x6 mm / 50x8 mm aluminium bus bar strip 75x6 mm aluminium bus bar strip 100x10 mm copper bus bar 10mm /12 mm thick 11 kv danger plates with clamps 33 kv danger plates with clamps 66 kv danger plates with clamps mesh fence of different sizes g.i. mesh fence of different sizes transformer oil confirming to is-335-1993 with ammendments up to date 33 kv ct of different ratios 33 kv pt of different ratios 33 kv vcb 33 kv c&r transformer panel with differential protection 33 kv c&r line panel 66 kv ct of different ratios 66 kv pt of different ratios 66 kv la set 66 kv isolator set with earthing blades 66 kv isolator set without earthing blades 66 kv c&r transformer panel 66 kv c&r line panel acsr weasel conductor acsr rabbit conductor acsr tiger conductor acsr wolf conductor acsr panther conductor street light / yard light 100 watt street light / yard light 250 watt led bulbs 9w isi mark led bulbs 15w isi mark led bulbs 30w isi mark led bulbs 50w isi mark lifting & pulling machine capacity 5 ton to 8 ton safety chart 3x2 ft, laminated board