Classic tenders ::
Get complete information related to latest access-control-reader Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic India tenders, private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding access-control-reader Tenders.
Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :21088432 c-icon18 Jun, 2021 Tender Value : NA
l-iconBageshwar - Uttaranchal Tender For construction installation of 06 bed icu demolishing brick work in cement mortar manually by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge. making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs compete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of engineer-in-charge. brick work with common burnt clay f.p.s. non modular bricks with cement mortar 1:4 1 cement : 4 coarse sand 12mm thick cement plaster of mix 1:6 1 cement : 6 fine sand providing and fixing of 1st class glazed ceramic wall tiles confirming to is standards, colour as per site requirement or approved by engineer-in-charge, over 12mm thick bed of cement mortar 1:3.mortar modular ceiling & wall partition panels: pre fabricated modular ceiling panels 50 mm thick puf panels between two sheets of 0.5mm ppgi/gi having puf density of 40kg/m3 with proper supports. ceiling panels will be fixed to the ceiling with channels, hangers & anchor fastner and interlocked with each other. panels including cutouts for lights, fans, ac grills etc as/if required. antibecterial paint: filling of all joints & cavities with metallic body filler on panels and wall putty on cemented walls and sanded flush to make smooth finish and coated with one coat of primer and 3 coat of antibecterial paint made of skk japan/ jotun. antistatic vinyl : seamless antistatic vinyl system on floor and wall upto 4 feet, 2mm thick homogenous vinyl, with perfectly curved flush rubber covings and, all joints welded properly including wall scatting. flooring wii be seamless with perfectly curved flash-covings, resistance to mechanical stress and dynamic loads and having becteria protection characteristics, 2mm thick, washable vinyl. it complies with en 649. vacuum system the medical vacuum system shall ensure the minimum pipeline. vacuum level of 450mmhg is maintained at the plant service connection point at the rated volumetric ‘free air’ flow rate with two pumps in standby. the bacteria filtration system shall be fitted in pipeline. two vacuum pumps shall be air-cooled, oil lubricated rotary vane type suitable for both continuous and frequent start/stop operation at nominal inlet vacuum levels of between 570mmhg and 720mmhg approx. central vacuum system with dual vacuum pump ir/aneast-iwata of vacuum of 745mm, with three phase motor 7.5 hp, storage tank of 1000 litre, and all required accessories vacuum gauge, vacuum pressure switch, silencer etc. cascading of vacuum pumps shall be achieved by measuring the vacuum level at the plant inlet with a pressure transducer. a mechanical back-up facility shall ensure continued operation in the event of a control system malfunction. the control system shall normally employ automatic rotation of the lead pump to maximise pump life and ensure even wear. vacuum filter station imported domnick hunter/ nitrogenium/trident make or equivalent . these filters are optimised for high-efficient removal of bacterial and other contamination solids and liquids from the suction side of vacuum pumps preventing damage to the pump and the potential biological infection of the surrounding environment. removed liquids are collected in a transparent flask which can be removed for sterilisation.the efficiency of the installed filter elements exceeds the 0, 005% penetration specified in htm 2022 for infectious disease units, when tested in accordance with bs 3928. gas specific terminal vacuum outlets with probes/adapters are designed & manufacturerd as per bs en13485. outlets shall be manufactured with a copper inlet pipe stub which is silver brazed to the outlet body. body shall be of one piece brass construction. for positive pressure gas services, the outlet shall be equipped with a primary and secondary check valve and the secondary check valve shall have break safe mechanism and also comply to en 737 pressure test standards and rated at minimum 200 psi in the event the primary check valve is removed for maintenance. the outlet assembly should have separate colour coding for each services and will accept only corresponding gas specific adaptors. all outlets shall be cleaned and de-greased for medical gas service, factory assembled and tested. the medical gas outlets should be of quick connecting and wall mounted modular type. flexible tubing having antistatic core as per iso with proper colour coded complete as per specifications. electrical distribution panel based on plc for controlling of vacuum pumps with electrical safety devices. the electrical control panel will be used for cascading of two vacuum pumps and electrical safety from abnormal electrical supply, single phase preventing system, phase reverse protection. electrical panel must have display for voltage and indicators. gas terminal oxygen outlets with probes/adapters complete as per specifications. all terminal units should conform to bs standards. terminal units intended for installation with the socket axis horizontal, ie wall mounted, include a non-swivel device so that directly connected equipment such as flow meters remain vertical; terminal units intended for installation with the socket axis vertical, for example in certain types of pendant, do not include a non-swivel device. medical graded copper pipes maxflow/rajco/mandev or equivalent shall be solid drawn, tempered, seamless, phosphorous deoxidized, non-arsenic and degreased for oxygen service. distribution copper pipe manufactured as per bsen:13348:2001. adequate supports shall be provided while laying pipelines to ensure that the pipes do not sag. all exposed pipes should be painted with two coats of synthetic enamel paint and colour codification. 22m od x 0.9 mm thk 15mm od x 0.9 mm thk 12mm od x 0.7 mm thk gas alarm panel to indicate any abnormality of gas pressures and other failures of the system. the alarm system shall be complete with display, sensor module and power supply. the alarm shall be complete with all indications controls, wirings, accessories etc. complete as required. 2 gas alarm panel with analog gauge display & hi-low-normal status. area valve box - 2 gas services with complete fittings, shaddles, pipes, gauge analog, without valves. valve box housing must be made of galvanized steel duly powder coated. isolation valve complete. the isolation valves will be non lubricated, 90 degree turn level, ball type, suitable for oxygen service. all valves shall be pneumatically tested for twice the working pressure and factory degreased for medical gas service before supply. 22 mm valve with brass nut & nipple 15 mm valve with brass nut & nipple butterfly valve with brass nut & nipple accessories oxygen bpc flowmeter with humidifier 0-15 litres/minute with adapter, tubing etc. back pressure compensated flow meter will be of accurate gas flow measurement with following features: control within a range of 0 – 15 lpm calibration within +/- 10% . it will meet strict precision and durability standard. the flow tube and shroud components shall be made of clear, impact resistant polycarbonate. flow tube shall have large and expanded 0 – 5 lpm range for improved readability at low flows. the humidifier bottle shall be made of unbreakable polycarbonate material and autoclavable at 121 degree centigrade temperature. ward vacuum unit 600ml wall mounted type. ward vacuum unit shall be of light weight and compact. the unit will consist of a regulator, 600 ml reusable collection jar, made of unbreakable poly carbonate material and fully autoclavable at 134 degree centigrade. a wall bracket for mounting the jar assembly on the wall. the vacuum regulator shall be infinitely adjustable and have vacuum gauge which indicates suction supplied by the regulator. safety trap shall be provided inside the jar to safeguard the regulator from overflowing. horizontal bed head panels 5 feet long for installation of outlets with provision for mounting necessary gas outlets. the bed head panel will be provided with cutout provision of electrical points, switches, wiring etc . the panels will be made in extruded aluminium profiles with powder coating and will have cutout provision for gas outlets, provision & fixing of electrical sockets 6/16 amp - 8 nos, one basket, one suction bottle clamp slider, cutout provision for nurse call system. nurse calling system 6 beded: hospital nurse calling system including call unit & indicator on each bed and main display unit with bed number at nursing station including power supply & wiring etc. track curtain partition system: bed partion system with aluminium extruded track system mounted in ceiling with all required hardware and stain free washable fabric curtains with net on top side. air conditioning: ceiling mounted cassette type inverter ac air conditioning: ceiling mounted cassette type inverter ac unit 3 star 2 tr with r410a. it provides 360 degree air flow with improved temperature distribution. sealed hinged door: manual sealed hinged door with ss sheet/ hpl sheet on both side & puf/honeycomb material will be filled between two sheets, door size 1500mm wide 2100mm height complete with double toughned glass vision window of 300mm x 300mm, ss door hinges make dorset/dorma, ss handle, door closer make dorset/dorma, door lock make dorset/dorma, sealing gaskett & automatic drop seal in bottom of door with required accessories. door frame will be aluminium extruded profile duly anodized/ ss304 with sealing gasket. sealed insulated glass window with motorized blind view window: - double insulated fixed glazing with not less than 5mm thick toughened glass on both the sides. window frame is powdered coated aluminium of approved shape flush mounted with wall panelling. motorized venetion blind between two glasses operated by wall mounted switch or remote. size of window - 1200mm x 1200mm electrical wiring internal electrical wiring as per requirement of icu, wiring make- finolex, havells, hpl, elecrical switch- sockets make- crabtree/north-west, anchor, with ot distribution electrical panel, ceiling lights led in ceiling of icu- 16 nos. power cable at ot with main distribution panel will be provided by customer manual surgical scrub station- 1 bay supply of creative-standard surgical scrub sink wall mounted, 1- bay made out of 16gauge ss304 stainless steel seamless welding, polished to stain finish complete with y strainers, jaquar make spouts & manual foot operated valve vijay-make system, non- corrosive metal composite pipe system with brass fittings.l- 1000mm x h-1380mm x d-575mm other items icu electronic bed with full five function- up- down adjustment, back rest adjustment, leg rest adjustment, trendlberg, reverse trendlberg operated by electronic remote and mounted on 125mm castors, 2 will be with brake, abs side railing, abs panel on head & leg. icu bed side locker deluxe type with one drawer and one cabinet, duly powder coated, mounted on rubber stamps. icu over bed table with laminated top and height adjusted thru manual geared handle, duly powder coated, mounted on 50 mm castors. instrument cabinet for icu for storage of medical equipments made of stainless steel ss304 and toughned glass. 3 seater waiting chair heavy duty made of stainless steel perforated sheet and heavy hand rest made of stainless steel. 10 kva on-line uninterrupted power supply ups with sinewave output, display unit and sealed maintenance free batteries with auto redundancy system, complete with wiring, trolley and installation. modular wall & ceiling panels: pre fabricated modular wall panels 80 mm thick puf panels between two sheets of 0.5mm ppgi/gi having puf density of approx 40kg/m3 with proper channel supports. ceiling panels will be 83mm 60+23mm thick puf corrugated between two sheets of 0.5mm ppgi having density of approx 40kg/m3 fixed to the wall thru channels, hangers & anchor fastner and interlocked with each other. panels including electrical conduits inside. and filling of all joints with silicon sealant. ms pipe structure, ppgi channels, supports, anchor fastners, rivets, hardware etc aluminium coving for all corners, made out of aluminium extruded profiles duly powder coated. complete electrical job including electrical wiring for lights and fans, supply of 4 nos ceiling fans, ceiling led surface lights 8 nos, wall switches and sockets for each bed. manual hinged aluminium door with compact high pressure laminate on bottom side and glass on top side or as per requirement of site, door size as per site approx 1500mm x2100mm complete with ss door hinges, ss handle, door closer, door lock with required accessories. door frame will be aluminium extruded profile duly anodized/ powder coated. openable sliding aluminium window with double slide, one for mosquito jali and one for glass as per requirement of site. window will be with aluminium moulded grill. window size as per site approx 900mm x900mm. mounted flush in modular wall paneling.

State Government

CTN :21045205 c-icon15 Jun, 2021 Tender Value : NA
l-iconLucknow - Uttar Pradesh Tender For supply and laying of aluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on m.s. clamps etc. of suitable size or as directed by the engineer-incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 sq. mm 3-1/2 core 35 sq. mm 3-1/2 core 50 sq. mm 3-1/2 core 120 sq. mm 3-1/2 core 150 sq. mm 3-1/2 core 240 sq. mm 3-1/2 core supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. the armouring of the cable shall be properly connected with the earth as per direction of engineer-incharge. 240 sq. mm 3-1/2 core 185 sq. mm 3-1/2 core 120 sq. mm 3-1/2 core 50 sq. mm 3-1/2 core 35 sq. mm 3-1/2 core 25 sq. mm 3-1/2 core supply and fixing of plain or pin type copper tin plated cable socket lug to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the engineer-incharge. 240 sq. mm 185 sq. mm 120 sq. mm 50 sq. mm 35 sq. mm 25 sq. mm s/f of thermoplastic cable junction box ip 66/ip 67 wheather proof for out door installation with knockouts for cable entry suitable for 16-50 mm size cable size of box 255x355x122 mm with out terminas all complete hensal/syntex or equivelent make all as per direction of e/icanalysis rate supply and wiring of submain with three number 2.5 sq.mm. pvc insulated 1100 v grade single core aluminium conductor cable in 20 mm dia. heavy guage cable in 20 mm dia. heavy guage rigid steel conduit on surface, with two number 8 swg gi earth continuity wire etc., complete in all respect. s/f of spn 30 amp main 3amp dg automatic changeover with current limiter accl switch with intelligent micro controller based design havels/indo/asian/l&t make all complete as per direction of e/ic. analysis rate supply and burying of 600mm x 600mm x 6mm g.i. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia g.i. pipe and funnel for watering and one earthing lead of two no. 8 to 10 swg gi wire in 15mm dia g.i. pipe up to switch board from appron to switch board the cost of g.i. pipe and g.i. wire will be extra 30cm square c.i. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of engineer-in-charge complete in all respect. supply and fixing of vertical down conductor of 32mm x 6mm g.i. strip etc. on approved clamps on surface for lightning conductor complete in all respects for two storeyed buildings. desining manufacuring supply installation testing & commissoning of emergency main pannel wit dg synchronization of 250, 160 & 125 kva complete with al material mantion as under as per direction of e/ic incomer from main lt panel 200a tp mccb 25 ka with o/l & s/c thermal magnetic release-03 nos spreader link-3nos rotary operating mechanism-3nos 200a fp contactor ac-1 duty-03nos multifunction meter with rs485 port-03 ct 200/5a-09 phase indicating lamp-09 on/off indicating lamp-09 control mcb-12 neutral link-03 incomer from 250kva dg set 400a tp mccb 36 ka with o/l & s/c thermal magnetic release-01 spreader link-01 rotary operating mechanism-01 400a fp contactor ac-1 duty-01 multifunction meter with rs485 port-01 ct 400/5a-03 phase indicating lamp-03 on/off indicating lamp-02 control mcb-04 neutral link-01 incomer from 160kva dg set 250a tp mccb 25 ka with o/l & s/c thermal magnetic release-01 spreader link-01 rotary operating mechanism-01nos 250a fp contactor ac-1 duty-01nos multifunction meter with rs485 port-01nos ct 250/5a-03nos phase indicating lamp-03nos on/off indicating lamp-02nos control mcb-02nos neutral link-01nos incomer from 125kva dg set 200a tp mccb 25 ka with o/l & s/c thermal magnetic release-01nos spreader link-01nos rotary operating mechanism-01nos 200a fp contactor ac-1 duty-01nos multifunction meter with rs485 port-01nos ct 200/5a-03nos phase indicating lamp-03nos on/off indicating lamp-02nos control mcb-04nos neutral link-01nos bus coupler-01 250a fp contactor ac-1 duty-01nos on/off indicating lamp-02nos control mcb-01nos neutral link-01nos bus coupler-02 200a fp contactor ac-1 duty-01nos on/off indicating lamp-02nos control mcb-01nos neutral link-01nos interlocking electrical interlocking between incomer contactors & bus coupler contactors-01nos auto load management system programmable logic control consisting of plc with 32 channel digital input & 32 channel digital output module and 8 channel analog input, voltage selector switch, motorised potentiometer, 12 window annunciator, 24 window micro facia, microprocessor based computer, switching mode power supply etc.-01 nos battery charger battery charger for dg sets with inbuilt trickle & boost facility, dc ammeter, dc voltmeter, selector switch, indicating lamp etc.-03nos outgoing on bus section-01 100a tp mccb 25 ka with o/l & s/c thermal magnetic release-07nos spreader link-07nos rotary operating mechanism-07nos outgoing on bus section-02 100a tp mccb 25 ka with o/l & s/c thermal magnetic release-07nos spreader link-07nos rotary operating mechanism-07nos outgoing on bus section-03 100a tp mccb 25 ka with o/l & s/c thermal magnetic release-04nos spreader link-04nos rotary operating mechanism-04nos accessories co-axial panel fan-06nos air filter-06nos space heater with thermostat-04nos panel light with door limit switch-04nos fabrication of panel indoor type compartmentalised design fabricated out of 14/16 gauge thick cold annameled cold rolled sheet steel with lockable doors at front & back & top/bottom gland plate alluminium busbar of electrolytic grade alluminium of size 40x10 for phase & 40x6 for neutral power wiring with required rating of copper flexible wire control wiring with 1.5 sq. mm. copper flexible wire panel accessories i.e. busbar sleeves, busbar supports, wire sleeves, thimbles, ferrules, terminal block, necessary hardwares, backelite sheet, acrylic sheet etc. modification in existing 125kva & 160 kva dg sets make chs for synchronization compatibility system including providing voltage regulars in dg sets current transformers in dg sets complete with reuqired material labour t&p etc all respects as per direction of e/ic deduct in item no-501i 501t and 506a to f when cables is passed through g.i./m.s. or hume pipe in road crossing or along the wall the cost of the g.i. pipe hume pipe is to be extra when and where required backup power supply of generator at jankipuram yojana sector j kursi road shtiht sasti apartment me purwa se stapit generataro hetu syncronizing panel lagane tatha apartment k avantiyo ko backup power supply of generator.
 Loading, Please wait...

Connect us via What's Up